Code
• The main motor (M1) is faulty.
E010
• The DC controller PCB is faulty.
• The drum motor (M0) is faulty.
E012
• The DC controller PCB is faulty.
• The waste toner feed screw has a fault.
• The DC controller PCB is faulty.
E013
• The fixing motor (M3) is faulty.
E014
• The DC controller PCB is faulty.
• The pickup motor (M2) is faulty.
E015
• The DC controller PCB is faulty.
• The waste toner case is full.
E019
• The hopper inside toner feeder motor
(M18) is faulty.
• The magnet roller drive clutch (CL1) is
faulty.
E020
• The developing assembly inside toner
sensor (TS3) is faulty.
• The DC control PCB is faulty.
• The hopper connector is disconnected.
• The cartridge inside toner feeder motor
(M6) is faulty.
• DC controller PCB is faulty.
E025
• The toner copy counter has an open
E030
circuit.
• The DC controller PCB is faulty.
• The option counter has an open circuit.
E031
• The DC controller PCB is faulty.
• The Copy Data Controller-A1 or the
Remoto Diagnostic Device II is faulty.
E032
• The DC controller PCB is faulty.
COPYRIGHT © 1999 CANON INC.
Cause
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Description
• No clock pulse arrives for 2 sec or more
after the output of the main motor drive
signal.
• No PLL lock signal (MOLCK) arrives
for 2 sec or more after the output of the
drum motor drive signal.
• The waste toner feed screw cannot
rotate, and the detecting switch (MSW2)
has been pressed multiple times within a
specific period of time.
• No PLL lock signal (M1-FG) arrive for 2
sec or more after the output of the fixing
motor drive signal.
• No clock pulse arrives for 2 sec or more
after the output of the pickup motor drive
signal.
• As many as about 50,000 pages worth of
images have been formed (in terms of
A4) without disposing of the waste toner
after a waste toner case full condition
(message indicated) has been identified.
• The absence of toner inside the
developing assembly has been detected
for 2 min or more after supplying the
developing assembly with toner.
• An overcurrent to the cartridge inside
toner feeder motor (M6) has been
detected twice for 10 sec each by the DC
controller PCB. (In response to the first
detection, the copier will indicate "Shake
the Toner Case.")
• The total copy counter is identified as
having an open circuit when it is driven.
• The options counter is identified as
having an open circuit when it is driven.
• The Copy Data Counter-A1 or the
Remoto Diagnostic Device II counter
function fails to operate.
• The Copy Data Controller-A1 or the
Remoto Diagnostic Device II is
disconnected.
13-251