Canon GP605 Service Manual page 91

Table of Contents

Advertisement

Related Error Code
E220
(activation error)
E222
(fluorescent lamp heater
error)
E211
(thermistor open circuit)
E215
(thermistor short circuit)
E219
(scanning lamp end of life)
COPYRIGHT © 1999 CANON INC.
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
[1] While in standby, the scanning lamp turns on. (detected in reference
to the voltage of FL-DTCT)
[2] During scanning, the scanning lamp turns off. (detected in reference
to the voltage of FL-DTCT)
[1] When the main power switch is turned on, the temperature does not
reach 70˚C or higher 5 min after the scanner heater has turned on
(HEAT-ON=1).
[2] While power is supplied, the temperature does not reach 75˚C or
more 3 min after the fluorescent lamp heater has turned on.
[1] When the main power switch is turned on, the temperature does not
reach 10˚C or higher 2 min after the fluorescent heater has turned
on (HEAT-ON=1).
[2] While power is supplied, a temperautre of 0˚C or lower is detected.
While the scanning lamp is off, a temperature of 170˚C or more is
detected.
While the scanning lamp is on, a temperature of 170˚C or higher is
detected by the thermistor.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
3-13