Canon GP605 Service Manual page 627

Table of Contents

Advertisement

Height of the Fixing Assembly Inlet Guide
1.5±0.2mm
Fixing
screw
Caution:
You would have to adjust the position of the inlet guide if you removed the inlet guide mount.
Do not loosen the fixing screw on the inlet guide to avoid adjustment. If the fixing screw has
been loosened for some reason, be sure to tighten it back in reference to the scale graduations
on the fixing assembly mount.
COPYRIGHT © 1999 CANON INC.
Figure 13-E201
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Fixing
screw
1.5±0.2mm