Advertisement

3) Remove the four screws [4], and detach
the reversal motor [5].
5.

Removing the Lower Feeder

Motor

1) Remove the front cover of the duplexing
unit.
2) Disconnect the connector [1], and remove
the two screws [2]; then, detach the lower
feeder motor [3].
6.

Removing the Horizontal

Registration Motor

1) Remove the duplexing unit from the
copier.
2) Remove the two screws [1], and detach
the upper cover [2].
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 PICK-UP/FEEDING SYSTEM
[4]
Figure 7-F805
[2]
[3]
Figure 7-F806
Figure 7-F807
[5]
[4]
[2]
[1]
[1]
[2]
7-79