CHAPTER 11 INSTALLATION
H.

Mounting the ADF

No.
1
Remove the face plate of the ADF
connector found on the copier's back
2
Insert the ADF connector into the socket
on the back of the copier.
3
With the ADF open, mount the ADF
document tray with two RS tightening
screws (M4 × 8; white).
Caution:
When mounting the ADF original
tray, fit the hook of the tray in the
copier's groove, and slide it to the
left before securing it in place with
screws.
4
Attach the ADF manual feed instructions
label to the manual feed tray of the ADF.
11-16
COPYRIGHT © 1999 CANON INC.
Work
Screws
Label
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Remarks
Connector
ADF document
tray
Hook