Drum Cleaner Unit

Construction
1.

Removing the Cleaning Blade

1) Open the front cover.
2) Slide out the process unit.
3) Remove the screw [1], and detach the re-
ciprocating arm [2].
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 IMAGE FORMATION SYSTEM
Cleaning blade
Separation claw
Figure 6-F701
[1]
Figure 6-F702
[2]