Canon GP605 Service Manual page 363

Table of Contents

Advertisement

Main power
switch ON
Fixing motor
(M3)
Main heater
(H1)
Sub heater
(H2)
150˚C
100˚C
70˚C
Figure 8-308 Sequence of Operations (error detection)
COPYRIGHT © 1999 CANON INC.
[1]E002
Control panel
power switch
ON
SLEEP
WMUP
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 FIXING SYSTEM
[1] The main thermistor does not detect
100˚C within 3 min after it has detected 70˚C.
[2] The main thermistor does not detect
100˚C within 3 min after it has detected 100˚C.
3 sec
2.5 min
Main power
switch OFF
8-21