D.
Others
1.
Removing the Original Size
Sensor (1/2)
1) Remove the copyboard glass.
2) Move the No. 1 mirror mount to the right
end.
3) Remove the two screws [1], and discon-
nect the connector [2]; then, detach the
original sensor unit [3].
4) Disconnect the connector [4] (one each),
and detach the original sensor (1/2) [5].
COPYRIGHT © 1999 CANON INC.
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
[3]
Figure 3-D501
[5]
[4]
[5]
Figure 3-D502
[2]