SDM-650B Satellite Modem
2.2.1 DATA I/O
For information and pinouts on the data connectors, refer to Chapter 3.
2.2.2 Remote (J6)
The remote connector on the modem is used to interface the Monitor and Control (M&C)
functions to a remote location. This interface can be either RS-232-C or RS-485. For a
complete discussion on the remote interface, refer to Chapter 3.
The remote interface is provided on a 9-pin female D connector. Screw locks are
provided for mechanical security of the mating connector. The remote connector is a Data
Circuit Terminating Equipment (DCE) interface.
Pin #
2.2.3 Fault (J7)
The fault connector on the modem is used to provide FORM C contact closures for the
purpose of fault reporting.
There are three FORM C summary fault contacts:
•
•
•
Refer to Chapter 4 for a complete discussion on monitored faults.
To obtain a system summary alarm, connect all FORM C contacts in parallel.
Rev. 5
RS-485
RS-232-C
Name
Pin #
1
GND
1
2
2
3
3
4
+RX/TX
4
5
-RX/TX
5
6
6
7
7
8
+RX/TX
8
9
-RX/TX
9
Modulator
Demodulator
Common equipment
Name
RD (RX)
TD (TX)
GND
DSR
RTS
CTS