B.1.4.5 Common Equipment Status
The common equipment status command causes a block of data to be returned, which
indicates the status of the common equipment.
Command:
Response:
B.1.4.6 Interface Receive Side Status
Command:
Response:
Note: This command is only valid when Buffer Control is enabled. See the "BUFF_"
command definition.
B–22
<add/CES_"cr"
>add/CES_"cr"
M&C_xxx"cr"
INT_xxx"cr"
TXC_xxx"cr"
BAT_xxx"cr"
PS1_xxx"cr"
PS2_xxx"cr"
PS3_xxx"cr"
MODE_xxxxxx"cr"
SW_x.xxx"cr"
SFLT_xx"cr""lf"]
<add/IRXS_"cr"
>add/IRXS_"cr"
OVFL_xxx"cr"
UNFL_xxx"cr"
SFLT_xx"cr""lf"]
SDM-650B Satellite Modem
Monitor and Control Module (OK/FLT)
Data Interface Module (OK/FLT)
Transmit Clock Loss (DS-1 only)
Battery (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Mode (LOCAL or REMOTE)
Software Version
Number of Stored Faults Logged (0 to 10)
Buffer Overflow (OK/FLT)
Buffer Underflow (OK/FLT)
Number of Stored Faults Logged (0 to 10)