Receive Signal Level; Current Sweep Value; Interface Buffer Fill Status; Interface Read Error Status - Comtech EF Data SDM-650B Installation And Operation Manual

Satellite modem
Table of Contents

Advertisement

Remote Control Operation
B.2.8.12 Receive Signal Level
Command:
Response:
B.2.8.13 Current Sweep Value
This command returns the current sweep value and the decoder lock status.
Command:
Response:
B.2.8.14 Interface Buffer Fill Status
Command:
Response:
Note: Available with buffer support hardware only.
B.2.8.15 Interface Read Error Status
This command returns 2047 BER. If data is not valid, the message "No_Data" is returned
instead of BER data.
Command:
Response:
Example:
Command:
Response:
B–64
<add/RSL_"cr"
>add/RSL_-nn.ndBm"cr""lf"]
<add/CSV_"cr"
>add/CSV_snnnnn"cr"
CD_xxx"cr""lf"]
Where:
s = + or - (sweep offset direction).
nnnnn = 0 to 25000.
xxx = OK or FLT (decoder lock status OK or FAULT).
<add/IBFS_"cr"
>add/IBFS_nn%"cr""lf"]
Where: nn = 1 to 99 (Relative to buffer depth).
<add/IRES_"cr"
>add/IRES_nE-e"cr""lf"]
Where:
n = 1 to 9 (error rate number).
e = 2 to 6 (exponent).
<add/IRES_"cr"
>add/IRES_2E-6"cr""lf"]