Remote Control Operation
B.2.8.2 Modem Faults Status (Summary)
This command returns the current overall fault conditions of the modem.
Command:
Response:
B.2.8.3 Modulator Status
The modulator status is returned as a block of data which indicates general status
information.
Command:
Response:
B.2.8.4 Demodulator Status
The demodulator status is returned as a block of data which provides general status
information.
Command:
Response:
B–60
<add/MFS_"cr"
>add/MFS_"cr"
DMD_xxx"cr"
MOD_xxx"cr"
CEQ_xxx"cr"
ITX_xxx"cr"
IRX_xxx"cr""lf"]
<add/MS_"cr"
>add/MS_"cr"
RF_xxx"cr"
MOD_xxx"cr"
AGC_xxx"cr"
SYN_xxx"cr"
BCLK_xxx"cr"
TCLK_xxx"cr"
ICH_xxx"cr"
QCH_xxx"cr"
SFLT_xx"cr""lf"]
<add/DS_"cr"
>add/DS_"cr"
DMD_xxx"cr"
CD_xxx"cr"
SYN_xxx"cr"
DSCR_xxx"cr"
ICH_xxx"cr"
QCH_xxx"cr"
BCLK_xxx"cr"
BERT_xxx"cr"
RSL_-nn.ndBm"cr"
CSV_snnnnn"cr"
SFLT_xx"cr""lf"]
SDM-650B Satellite Modem
Demodulator (FLT/OK)
Modulator (FLT/OK)
Common Equipment (FLT/OK)
Interface Transmit Side (OK/FLT)
Interface Receive Side (OK/FLT)
RF Output (ON/OFF) actual status not
configured
Module missing or will not program
(OK/FLT)
AGC Leveled (OK/FLT)
Carrier Synthesizer (OK/FLT)
Bit Clock (OK/FLT)
Transmit Clock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
Synthesizer Lock (OK/FLT)
Descrambler (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Bit Clock (OK/FLT)
BER Threshold (OK/FLT)
Receive Signal Level (Level or No Data)
Current Sweep Value
Number of Stored Faults Logged (0 to 10)
Rev. 6