Date; Clear Stored Faults; Ber Threshold - Comtech EF Data SDM-650B Installation And Operation Manual

Satellite modem
Table of Contents

Advertisement

SDM-650B Satellite Modem
B.1.3.18 Date
Command:
Response:
Status Only: <add/DATE_"cr"
Response:
Example: Set modem 235 date to 11/30/87.
Command:
Response:
B.1.3.19 Clear Stored Faults
This command is used to clear all stored faults logged by the modem.
Command:
Response:
B.1.3.20 BER Threshold
Command:
Response:
Status Only: <add/BERT_"cr"
Response:
Rev. 6
<add/DATE_mm/dd/yy"cr"
>add/DATE_mm/dd/yy"cr""lf"]
>add/DATE_mm/dd/yy"cr""lf"]
Where:
mm = month.
dd = day.
yy = year.
<235/DATE_11/30/87"cr"
>235/DATE_11/30/87"cr""lf"]
<add/CLSF_"cr"
>add/CLSF_"cr""lf"]
<add/BERT_xxxx"cr"
>add/BERT_xxxx"cr""lf"]
>add/BERT_xxxx"cr""lf"]
Where: xxxx = NONE or 1E-n (n = 3, 4, 5, 6, 7, or 8 [exponent of threshold]).
Remote Control Operation
B–13

Advertisement