NEC Univerge SV8100 Features And Specifications Manual page 633

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
20-31-02
Timer Class Timer Assignment –
Callback / Trunk Queuing Cancel
Time
20-31-03
Timer Class Timer Assignment –
CAR/SIE/Virtual Extension Delay
Interval
20-31-04
Timer Class Timer Assignment –
Intercom Interdigits Time
(Intercom I/D Timer)
20-31-05
Timer Class Timer Assignment –
Trunk Interdigits Time (Trunk I/D
Timer)
20-31-06
Timer Class Timer Assignment –
Hotline Time Start Time (Hotline
Start)
20-31-07
Timer Class Timer Assignment –
Ring No Answer Alarm Time
20-31-08
Timer Class Timer Assignment –
DIL/Incoming Ring Group No
Answer Time
20-31-09
Timer Class Timer Assignment –
DID Ring-No-Answer Time
20-31-10
Timer Class Timer Assignment –
Hold Recall Time (Non Exclusive
Hold)
Flexible Timeouts
Description/Comments
The system cancels an extension
Callback or Trunk Queueing
request after this time.
CAR Keys/SIE Keys/Virtual
Extensions set for Delayed
Ringing (refer to
15-11: Virtual
Extension Delayed Ring
Assignment) ring the extension
after this time.
When placing Intercom calls,
extension users must dial each
digit during this time.
The system waits for this time to
expire before placing the call in a
talk state (Call Timer starts after
time expires, Voice Over and
Barge-In are not allowed until after
time expires).
A Ringdown extension
automatically calls its programmed
destination after this time.
If a trunk rings a multiline
telephone longer than this time,
the system changes the ring
cadence. This indicates to the
user that the call has been ringing
too long.
A DIL that rings its programmed
destination longer than this time
diverts to the DIL No Answer Ring
Group (set in Program 22-08).
In systems with DID
Ring-No-Answer Intercept, this
time sets the Ring-No-Answer
time. This is the time a DID call
rings the destination extension
before rerouting to the intercept
ring group.
A call on Hold recalls the
extension that placed it on Hold
after this time. This time works
with the Hold Recall Callback Time
(Program 24-01-02).
Assigned Data
1
0~64800 (seconds)
(default = 64800)
0~64800 (seconds)
(default = 10)
0~64800 (seconds)
(default = 10)
0~64800 (seconds)
(default = 5)
0~64800 (seconds)
(default = 5)
0~64800 (seconds)
(default = 60)
0~64800 (seconds)
(default = 0)
0~64800 (seconds)
(default = 20)
0~64800 (seconds)
(default = 90)