Program
Program Name
Number
84-19-26
SIP Extension CODEC
Information Basic Setup – TX
Gain
84-19-27
SIP Extension CODEC
Information Basic Setup – RX
Gain
84-19-28
SIP Extension CODEC
Information Basic Setup – Audio
Capability Priority
84-19-31
SIP Extension CODEC
Information Basic Setup – DTMF
Payload Number
84-19-32
SIP Extension IP CODEC
Information Basic Setup – DTMF
Relay Mode
84-19-33
SIP Extension IP CODEC
Information Basic Setup –
Number of G.722 Audio Frames
84-19-34
SIP Extension IP CODEC
Information Basic Setup – G.722
Voice Activity Detection Mode
84-19-35
SIP Extension IP CODEC
Information Basic Setup – G.722
Jitter Buffer (min)
IP Single Line Telephone (SIP)
Description/Comments
Define TX Gain Values – Adjusting
this value increases or decreases
volume levels for the receiving
party. Consult the UNIVERGE
SV8100 Programming Manual for
Transmit Gain scale to set
acceptable value.
Define to RX Gain Values –
Adjusting this value increases or
decreases volume levels for the
sending party. Consult the
UNIVERGE SV8100 Programming
Manual for Transmit Gain scale to
set acceptable value.
Define Audio Priority. Consult the
UNIVERGE SV8100 Programming
Manual for Transmit Gain scale to
set acceptable value.
Define the DTMF Payload
Number.
Define the DTMF Relay Mode.
Define the number of Audio
Frames for G.722 CODEC.
Enable/Disable G.722 Voice
Activity Detection Mode.
Define the minimum setting for the
G.722 Jitter Buffer.
Assigned Data
1
0~30 =
(-19 dB ~ +10 db, Auto)
0 = Auto Adjust
1 = -19 dB (-49dBm)
:
20 = 0 db (-30 dBm)
:
29 = +19 db (-21 dBm)
30 = +10 db (-20 dBm)
(default =20)
0~40 =
(-20dBm ~ +20dBm)
0 = -20 dBm
1 = -19 dBm
:
20 = 0 dBm
:
39 = +19 dBm
40 = +20 dBm
(default = 20)
0 = G.711_PT
1 = G.723_PT
2 = G.729_PT
3 = G.722
4 = G.726
5 = Not Used
(default = 0)
96~127
(default = 96)
0 = Disable
1 = RFC2833
(default = 0)
1~4
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
(default = 3)
0 = Disable
1 = Enable
(default = 0)
0~160ms
(default = 30)