UNIVERGE SV8100
Off-Hook Signaling
Programmable Function Keys
Secondary Incoming Extension
User Programming Ability
Virtual Extensions
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
15-07-01
Programmable Function Keys
20-06-01
Class of Service for Extensions
Call Appearance (CAP) Keys
Description/Comments
Assign functions to multiline
terminal line keys.
Assign a Class of Service (1~15)
to extensions.
Assigned Data
1
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
(
08 + XXXX = CAP
key where XXXX is the
CAP orbit number
0001-9999)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1