PCPro can be logged in with only one user. This is allowed only if no other users are
logged into programming mode (PCPro, WebPro, or Phone). Also, if a user is connected to
the switch via PCPro, no other user can log in through PCPro, WebPro, or Phone
Programming.
Only one PCPro/WebPro/Handset can be programming the switch anytime.
When programming via WebPro/PCPro, some data requires you to logout before the switch
fully applies the changes. These Programs are: 10-21-2, 11-02 (for directory dial), 11-04
(for directory dial), 13-04 (for directory dial), 14-04, 15-05, 15-15, 16-02, 23-02, 31-02,
41-02, 41-17, 47-02, 47-03, 82-11 and 83-11.
In the card configuration window, if you click a card type in the main menu, the menu
closes. You must mouse over the card type to open the submenu to list all cards of that
type.
To access the modem over K-CCIS, route the modem access service code to the target
switch. Do not call a station that is call forwarded to the service code. When accessing the
modem over K-CCIS, enter the service code to be dialed in PC Pro.
PC Pro follows the PC dialing properties. If dialing a service code, you must turn off the dial 9 for
outside line and area code inclusion or PC Pro will dial these digits as well.
Some program items require second initialization of the KTS before they take effect. These
Programs are: 10-12-01, 10-12-02, 10-12-03, 10-12-04, 10-13-01, 10-13-02, 10-13-03,
10-14, 10-15, 10-16-01, 10-16-02, 10-16-03, 10-16-04, 20-01-03, 47-01-01, 80-01,
80-02-01, 80-02-02, 80-02-03, 80-02-04, 80-03, 80-04, 84-03-01, 84-03-02, 84-03-06,
84-03-07, 84-03-08, 84-05-01, 84-05-02, 84-06-01, 84-06-02, 84-06-03, 84-06-04,
84-06-05, 84-06-06, 84-06-07, 84-06-08, 84-06-09, 84-06-10, 84-06-11, 84-09 and 84-10.
PC Programming
These caution statements do not apply to Version 2.0 or higher software.
Failure to properly install and program ports higher than 64 (as
described below) can corrupt the SV8100 database.
If the PZ-ME50-US is not physically installed on the CD-CP00-US,
do not attempt to change the PCPro database configuration to
indicate that the PZ-ME50-US is installed on the CD-CP00-US,
program ports 64 and higher and then upload the PCPro
configuration to the SV8100 system. This process can corrupt the
SV8100 database. Refer to the next bullet for the proper installation/
programming procedure.
To properly install and configure the PZ-ME50-US; first install the
PZ-ME50-US on the CD-CP00-US. Next, you must reload the system
software. With the PZ-ME50-US installed, a portion of the main
software is loaded onto the PZ-ME50-US.
Before attempting to program the ports above 64 using PCPro, a new
download must be performed after the PZ-ME50-US is installed.
Issue 5.0
2 - 1003