UNIVERGE SV8100
Alarm Report Heading
LVL
NO
STAT
DATE
TIME
ITEM
UNIT
SLT
PRT
PARAMETER
Item Name
PKG Installation
ISDN Link
CD-CP00-US – LAN Link
Blocking
System Data Change
System Start Up
SMDR Link
STA
TRK
LNK
NET
System Information
The system can print a report of the blades installed, the port assignments, and the port types. This
information is sent to the extension defined in Program 90-13.
Alarm Reports
Table 2-3 Alarm Report Definitions
Alarm Type (MAJ = Major, MIN = Minor)
Number of Alarm (4-digit)
Status (REC = Recovered, ERR = Error, WAR = Warning
Date the Alarm Occurred
Time the Alarm Occurred
Name of the Alarm
Name of the Blade
Chassis Slot Number
Chassis Port Number
Related Information
Table 2-4 Alarm Report Item Definitions
Blade is removed or inserted.
ISDN Line failure is detected.
CD-CP00-US – Lan connection failure is detected.
Terminal Failure may have occurred because terminal blocking is detected.
Terminal is unplugged or wire is disconnected.
System Upgrade performed or Programming change.
System is reset.
Connection failure is detected between the CD-CP00-US and SMDR printer device.
DSP for IP Station Call were all busy.
DSP for Trunk Call were all busy, includes SIP trunks.
DSP for Net-Link Call were all busy.
DSP for CCISoIP Networking Call were all busy.
Definitions
Definition
Issue 7.0
2 - 31