Battery Backup - System Memory - NEC Univerge SV8100 Features And Specifications Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Description
The battery on the CD-CP00-US retains the Clock/Calendar and Last Number Redial (LNR) buffers for
each station when the CD-CP00-US encounters a power loss. With a fully charged battery, the settings
are retained for approximately three years.
The system programmed memory (Customer Database) is stored in Nonvolatile Memory and can be
erased only by performing a First Initialization.
For additional storage time, the database and Caller ID History can be copied to the Compact Flash card on the
CD-CP00-US.
Conditions
The battery on the CD-CP00-US should be removed during long term storage but must be
installed (protection against loss of power) just before blade installation to provide battery
backup for System Memory.
When fully charged, the battery retains System Memory for approximately three years.
You should replace the CD-CP00-US battery every three years.
During normal operation, the battery is continually recharged using a built-in charging
circuit from the CD-CP00-US.
To prevent loss of the Caller ID History, you should save the database before storing the
CD-CP00-US.
Battery backup on the CD-CP00-US does not protect the following:
Callback
Off-line Status (for programming system or station assignments)
Repeat Redial
Trunk Queuing/Camp-On
Caller ID History
Default Settings
None
 The battery must be installed on the CD-CP00-US prior to programming a customer database.
Battery Backup – System Memory
Battery Backup – System Memory
Issue 7.0
2 - 139