13 Ethernet
Critical
This level is set for the most important ports, whose power supply is always
guaranteed. Set this value for a port for which power must always be supplied.
High
Power is supplied to ports whose priority is set to
frequently used. Ports with no priority specified are assumed to be high-priority ports.
If the amount of power that can be supplied is no longer sufficient, the supply of
power to high-priority ports stops later than it does for low-priority ports. Of the
high-priority ports, the higher the port number, the earlier the supply of power stops.
Low
Power is supplied to ports whose priority is set to
infrequently used. If the amount of power that can be supplied is no longer sufficient,
the supply of power to low-priority ports stops earlier than it does for high-priority
ports. Of the low-priority ports, the higher the port number, the earlier the supply of
power stops.
Never
The power supply unit stops and the PoE functionality is disabled. Set this level for
ports for which the PoE functionality is not used. For the never-priority ports, power is
never supplied even when plenty of power is available.
(2) Priority given to the powered ports
This function secures power supply to the ports that have already been connected, without
depending on the priority set for each port.
For an AX2200S series switch, powered ports take precedence over other ports in the
same system (system 1 or system 2).
For an AX1240S series switch, powered ports take precedence over other ports on the
entire switch.
The
power inline priority-control disable
priority to the powered ports.
When priority is given to the powered ports, power is first supplied to a power-receiving
device connected earlier. When the total power consumption is over 370.0 W, even if a
power-receiving device is connected to a port with priority set as
be supplied.
Therefore, the priority setting configured by the
disabled, and those ports are simply recognized as ports for which power is to be supplied.
If the
power inline never
Even when priority is given to the powered ports, a trap for notifying a warning for power
supply is issued.
The setting by the
enabled after the Switch is restarted.
202
configuration command is set, power is not supplied.
power inline priority-control disable
high
. Set this level to ports that are
low
. Set this level to ports that are
configuration command is used to give
critical
power inline
configuration command is
configuration command is
, power will not