Alaxala AX2200S Series Configuration Manual page 151

Table of Contents

Advertisement

Figure 11-1 Transitions of automatic LED operation [AX2200S]
Figure 11-2 Transitions of automatic LED operation [AX1250S] [AX1240S]
The trigger for automatic operation depends on Table 11-4 Trigger for automatic operation
and the resulting behavior. Transition conditions include trigger for automatic operation and
timer control.
1.
Conditions for transition to normal brightness
Transition to normal brightness occurs according to any of the triggers shown
in Table 11-4 Trigger for automatic operation and the resulting behavior.
2.
Conditions for transition to power saving brightness [AX1250S] [AX1240S]
Timer control is used for transition from normal brightness to power saving
brightness. LEDs transition to power saving brightness 60 seconds after the last
trigger for automatic operation.
This is performed even when triggers for automatic operation of transition to normal
brightness continuously occur.
11 Power Saving Functionality