IP Telephone Programming

250 Station IP Data Assignment

250 Station IP Data Assignment
Program 250 is used to set up the IP address of the specific IP phone card to support IP-Telephone feature.
The IP Phone Prime DN must be assigned using Program 200 before you configure the BIPU card.
1. From the Program Menu, click
IP-Telephone > Station IP Data.
The Station IP Data
Assignment screen displays
(shown right)
2. Enter Program 250 data.
3. Click Submit.
F
IELD
Prime DN
01 Station ID
02 Station IP Address
Type
03 Station IP Address
04 Automatic assignment
of Station ID
8-6
D
ESCRIPTION
Enter the IPT Prime Directory Number (PDN)
Possible values: Up to five digits.
Station ID is set from the IPT to match its PDN in station Program '369
Hold-2-FB05'. The station ID is the same as the station PDN unless there is
more than one CTX system having BIPU-Ms on the same network. In this
case the station ID for each IP telephone must contain the CTX Node
ID+PDN.
Possible values: Up to five digits.
Select the Station IP Address to be static 'fixed' or dynamic in which case it
obtains an IP address from a DHCP server.
Possible values: Fix or Any (default)
Enter the Station static IP Address if a static address is needed per 02
Station IP Address Type.
Use Automatic when the IPT has no Station ID. Use "Not Automatic" when
IPT has station ID in the IPT setting. In Program 150, FB01 is the same
parameter for system.
When "Don't Care" is set, FB01 of program 150 precedes FB04 in Program
250.
Enabling FB01 in Program 150 is equal to using "automatic" in FB04 of
Program 250. Disabling FB01 in Program 150 is equal to "not automatic" of
FB04 of Program 250. When IPT requests to connect to a Strata CTX with
no station ID, CTX searches for a PDN that is set in this parameter as
"automatic", and send the PDN to the IPT, and IPT records it in the IPT
setting.
Possible values: Permitted, NotPermitted or DontCare (default)