Programs 801~803
Button
Sequence
801
Network Jack LAN
Device Assignments
,
'
Cyq
801-00
LAN Port Number
n,
Cyq
801-01
Protocol
, n,
A7
Cyq
801-02
PC Operation Type
, n,
A7!
Cyq
801-03
Data Flow
, n,
A7"
Cyq
801-04
Server Port Number
, n,
A7#
Cyq
801-05
Client IP Address
801-06
A7$ÃA7%ÃA7&Ã
, n,
ÃA7'
Cyq
801-07
801-08
801-09
Write Retry Number
, n,
A7(
Cyq
801-10
Write Retry Number
, n,
A7
Cyq
801-11
Write Retry Number
, n,
,
A7
Cyq
803
IO Logical Device
Assignment
,
'"
Cyq
803-00
Logical Device
Number
n,
Cyq
13-92
Value(s)
n =
1~12 (default = no value)
n =
1. TCP (default)
2. UDP
n =
1. Server (default)
2. Client
n =
1. Synchronization
2. Asynchronization
(default)
n =
0~65535 (default = 0)
n =
0~255 (default = 0)
n =
0~65535 (default = 0)
n =
0~10 (default = 1)
n =
0~10 (default = 1)
Cyq
n =
100 = SMDR
300 or 301 = SMDI
200~208 = CTI LAN
Devices of PCs (default =
no value)
400 = BLF
500 = DSS
This screen assigns the LAN parameters for the PC applications
connected to the BECU Network Jack through a LAN or Hub.
Enter the port number of the LAN device to be assigned. Refer to
Program 803 SMDR SMDI CTI Port Assignments.
Notes
•
Program the local port number for LCD Control of Voice Mail
•
Use the same Device Port No. (11) for Network BLF.
•
Use 10 for Network TPI
•
Use 12 for Network DSS
Network BLF and DSS are available only with CTX Release 1.3 or
higher software and with CTX WinAdmin Release 1.3 or higher
software.
Select communication Protocol.
Note
Select UDP for Network DSS.
Enter the application PC type: Server or Client.
Enter the data flow protocol that should take place between the CTX
and PC. If the PC is a CTX, CTI application assign "Asynchronization"
to data flow.
Enter the Server Port Number and proceed to 07 Read Retry
Number. This field is required if Server was selected in 02 PC
Operation Type above. If not, leave this field blank and proceed to 05
Client IP Address.
Note
Use 6000 for Network BLF, 3000 for Network DSS, and 5000
for Network TPI.
Enter the Client LAN IP Address. This field is required if Client was
selected in 02 PC Operation Type above.
0~255 for each octet (default = 0)
Enter IP address of Stratagy iES32 or SES.
Enter the Client Port number. This field is required if Client was
selected in 02 PC Operation Type above.
Set the Read Retry counter to (1~10).
Set the Write Retry counter to (1~10).
This screen is used to assign:
1. SMDR and SMDI to logical device and BSIS, RS-232 port
numbers.
2. CTX WinAdmin, ACD sever, and Attendant Console to BECU,
Network Jack logical device and LAN port numbers.
Enter the 3-digit logical device number for SMDR, SMDI, and LAN
device or PC application. See
SMDR: 100
SMDI: 300 or 301
CTI LAN devices or PCs can be assigned to any of the 9 LAN devices
numbers available: 200~208.
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Summary
"Device Table"
on
page 13-93