2. On the WinAdmin PC, create a Vftp folder under the WinAdmin folder: After you create the folder, the
directory path should be C:\ctx\WinAdmin\Vftp
3. Download the "CreateFTPVdir" from Toshiba TSD Internet FYI site. On FYI, click Technical Services
> Software (Strata Systems) > CTX IP Firmware > VFTP Script.
4. Copy the "CreateFTPVdir" to the Vftp folder on the WinAdmin PC: (C:\ctx\WinAdmin\Vftp).
5. On the WinAdmin PC, create a CTXIPUPDATE folder under the WinAdmin folder. After creation the
directory path should be C:\ctx\WinAdmin\CTXIPUPDATE.
6. Run "CreateFTPVdir" by double clicking on it. This executable file will create the FTP virtual
directory needed for IP updates.
7. You can check the FTP directory from: Control Panel > Administration Tools > Internet Information
Services > Local Computer > FTP Sites > Default FTP > CTXIPUPDATE.
Download the IP Firmware files and store them on the WinAdmin PC
1. Download the appropriate DIPXXXX and BIPUXXX firmware update files from TSD FYI, click
Technical Services > Software (Strata Systems) > CTX IP Firmware.
2. Copy the DIPXXXX and BIPUXXX to the CTXIPUPDATE folder on the WinAdmin PC
(C:\ctx\WinAdmin\CTXIPUPDATE\. These files will be accessed during the IP update processes.
BIPU Update
Important!
Complete all
Copy the BIPUXXX file into the WinAdmin PC CTXIPUPDATE directory.
Notes
• The directory location should be C:\Ctx\W inAdmin\CTXIPUPDATE. The drive letter must be the
drive on which WinAdmin is installed.
• (XXX in the BIPU file name is the BIPU firmware version level).
From the WinAdmin PC perform the BIPU update
1. Select Maintenance > Components > Cabinet. Force Disable the BIPU cabinet slot. This will also cause
all IP telephones that are connected to the disabled BIPU to be in the "MAKE BUSY" mode.
2. Select IP Telephone > BIPU Program Update.
3. Select the BIPU card slot and BIPU-M card type.
Note
Only BIPU-M1A can be updated. Only BIPU-M1A card slots will be shown with WinAdmin 2.1F
or higher. The BIPU type selection is not required.
4. Select Local WinAdmin (radio button)
5. Enter the ftp user login Name and Password.
Note
If in doubt, create a new Window logon User Name and password and use it in Step 5.
6. The IP address of the WinAdmin PC is inserted automatically.
7. From Data Directory box enter: CTXIPUPDATE
8. From File Name box enter: BIPUXXX
9. Click Start and observe the update status: Getting Updated file\Updating\Finished
Updating\Resetting\idle.
Notes
• It could take 1 to 5 minutes to update the BIPU
• If an error occurs, recheck file names, locations etc. and try again.
Strata CTX Programming - Part 4: Appendices 04/03
"Prerequisites"
on
page E-4
Software and Firmware Updates
IP Telephone/BIPU Firmware Update Procedures
before you do the following.
E-5