Network Dss (R1.3 And Higher) - Toshiba Strata CTX Programming Manual

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

Network DSS (R1.3 and higher)

When you set up Network DSS, you assign the DSS numbers in the local CTX first. Then, once you
network the remote CTXs, they will use the DSS numbers set in the local CTX. Prior to R1.3, DSS
numbers had to be assigned to each remote CTX.
An example of how to set up Network DSS is shown in
local/host site, then CTX670-2 and CTX100 become remote sites.
Local
(CTX670-1)
Program 916 - Set
IP Address = 192.168.1.44
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
= 3000
Program 670 - 00 LAN
Port = 12
Strata Net
Node ID: 16
LAN / Switch / Hub
Example Procedure to Assign Network DSS in Node 16
1. Program 916 assigns IP Addresses.
2. Program 803 assigns Network DSS Port (Port 12).
3. Program 801 assigns DSS Server Port 3000.
4. Program 651~656 and 102 assign Strata Net Node IDs and network (QSIG).
5. Program 670 assigns Remote Nodes (17, 18) and their DSS Server Ports.
6. Program 205 or 215 assigns Network DSS keys on stations.
7. Repeat steps 1~6 for nodes 17 and 18. Note: Steps 4 and 5 assign parameters for remote nodes only
Figure 9-4
Network DSS Example
Use the following steps to program Network DSS from WinAdmin:
1. Create the Node ID in
If you have already created the Node ID using QSIG, skip Step 1 and go to the next step.
Note
2. Use Program
"916 IP Configuration" on page 10-14
3. Program the CTI Port for Network DSS. From the Program menu, select System > I/O Device. Refer to
"803 SMDR SMDI CTI Port Assignments"
• 00 Logical Device No. = 500 (DSS)
• 01 Device Connection = LAN
• 02 Device Port No. = 12
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
Remote
(CTX670-2)
Program 916 - Set IP
Address = 192.168.1.43
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
= 3000
Program 670 - 00 LAN
Port = 12
Program 670
QSIG
Remote Node ID: 17
IP-Network
LAN / Switch / Hub
"102 Flexible Access Codes"
on
page
Figure
9-4. In this example, if CTX670-1 is the
Program 916 - Set IP
Address = 192.168.1.53
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
= 3000
Program 670 - 00 LAN
Port = 12
QSIG
IP-Network
LAN / Switch / Hub
on
page
4-3.
to set up the IP address for each CTX.
4-27.
Services
Networking
Remote
(CTX100)
Program 670
Remote Node ID: 18
6591
.
9-35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx100Strata ctx670

Table of Contents