Station
ISDN
F
IELD
Primary DN
01 PDN Equipment No.
02 ISDN Channel
Group
03 ISDN Protocol
04 Type Connection
05 BRI Station COS
•
Day1 COS
•
Day2 COS
•
Night COS
06 BRI Station DRL
•
Day1 DRL
•
Day2 DRL
•
Night DRL
07 BRI Station FRL
•
Day1 FRL
•
Day2 FRL
•
Night FRL
5-32
D
ESCRIPTION
Enter the PDN. When a required DN is not programmed, the DN is regarded as a
new station. The System assigns default data as defined in
Possible values: Up to 5 digits (default = no value)
Enter the BRI equipment number assigned to this PDN. This is the cabinet, slot,
and circuit number of the RBUU/RBUS or RBSU/RBSS interface PCB to which the
the PDN is, or should be, assigned. Enter data as xxyyzz:
Example: If the PDN should be a assigned to a BDKU in cabinet 5, slot 2, circuit 3;
enter 050203.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
Enter the ISDN Channel Group number.
Possible values: 1~32 (CTX100), 1~48 (CTX670 Basic)1~128 (CTX670 Exp.)
(default = 1)
Select the ISDN protocol. Only Bearer capabilities specified by the protocol can be
entered in this field. The Initial value for ISDN Protocol corresponds to information
set in the hardware level.
Possible values: Nat'l ISDN (default), ETSI, TTC or Nat'l ISDN Nortel
Note
National ISDN = North America, ETSI = England and TTC = Japan.
Select connection type.
Possible values: Point to point (default) or Point to Multi-point
Select the BRI Station COS assignments.
Possible values: 1~32 (default = 1)
Select the BRI Station DRL assignments.
Possible values: 1~16 (default = 1)
Select the BRI Station FRL assignments.
Possible values: 1~16 (default = 1)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
.
217 ISDN Station Data