Telephone Button Programming
300 Series Programs
Programs 303~315
Button
Sequence
315
T1 Trunk Card
,
" "
Cyq
315-00
T1 Equipment
Location
xxyy,
Cyq
315-01
Coding Format
, n,
A7
Cyq
315-02
Frame Format
, n,
A7!
Cyq
315-03
Time Slots
315-04
Receive PAD
, n,
,
A7$
Cyq
315-05
Send Pad
, n,
A7#
Cyq
Programs 316~317
Button
Sequence
316
Shared D Channel
,
" %
Cyq
316-00
Channel Group
n,
Cyq
13-62
(continued)
Value(s)
xxyy
xx = Cabinet 01,
yy = slot 01, 03, 05, or 07
...or xx = Cabinet 02~07,
yy = slot 01, 03, or 05
n =
1. None
2. PZC
3. B8ZS (default)
4. ZCS
n =
1. None
2. SF mode
3. ESF mode (default)
n =
1. None
2. 8 Time Slots (default)
3. 16 Time Slots
4. 24 Time Slots
n =
1. None
2. Plus 6 dB
Cyq
3. Plus 3 dB
4. Zero dB (default)
5. Minus 3 dB
6. Minus 6 dB
7. Minus 9 dB
8. Minus 12 dB
9. Minus 15 dB
n =
1. None
2. Plus 6 dB
3. Plus 3 dB
4. Zero dB (default)
5. Minus 3 dB
6. Minus 6 dB
7. Minus 9 dB
8. Minus 12 dB
9. Minus 15 dB
Value(s)
n =
1~32 (CTX100)
1~48 (CTX670 Basic)
1~128 (CTX670 Exp.)
This command assigns T1 Trunk Card Data to the system.
Enter the RDTU PCB equipment location as xxyy:
Example: If the RDTU is installed in cabinet shelf 5, slot 3, enter
0503.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
Select the Coding Format.
Select the Frame Format.
Set the number of Time Slots to be used.
Select the Receive PAD values.
Select the Send PAD values.
The PRI Interface can be extended to include an additional PRI card
to expand the total number of channels to 47 on a Channel Group.
This second PRI may optionally offer a backup D channel.
Channel Group Number.
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Summary
Summary