Telephone Button Programming
500 Series Programs
Programs 500~577
Button
Sequence
513-03
B Record for Incoming
Call
, n,
A7"
Cyq
513-04
Abandoned Call
Record Output
, n,
A7#
Cyq
513-05
Display Transferred
Call Records
, n,
,
A7$
Cyq
514
SMDR for OLG
Assignment
,
$ #
Cyq
514-00
OLG
n,
Cyq
514-01
SMDR Record
Display
, n,
A7!
Cyq
514-02
Outgoing Records
, n,
,
A7"
Cyq
514-03
Outgoing Records
, n,
,
A7"
Cyq
515
View BIOU Control
Relay Assignment
,
$ $
Cyq
515-00
BIOU (1 or 2)
n,
Cyq
515-01
BIOU Relay 1 or 5
, n,
A7
Cyq
515-02
BIOU Relay 2 or 6
, n,
A7!
Cyq
515-03
BIOU Relay 3 or 7
, n,
A7"
Cyq
515-04
BIOU Relay 4 or 8
, n,
,
A7#
Cyq
13-78
(continued)
Value(s)
n =
1. Enable
2. Disable (default)
n =
1. Enable
2. Disable (default)
n =
1. Source (default)
2. Destination
Cyq
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1. Enable (default)
2. Disable
n =
1. Enable (default)
2. Disable
Cyq
n =
1. Source (default)
2. Destination
Cyq
n =
1 or 2
n =
1. Not Use (default)
2. Ext Paging
3. Night Bell
4. Night Relay
5. Door Lock
Cyq
Enable B Record generation for incoming calls with or without
incoming SMDR being enabled.
Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.
Select whether to charge a transferred call to the source or
destination party.
This command assigns SMDR parameters for OLGs.
Specify the OLG for which to set SMDR parameters.
Enable SMDR Record Display.
Enable to generate records for outgoing calls. SMDR Record Display
must be on.
Enable to apply the SMDR record of a transferred call to its source or
its destination.
This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.
Notes
•
BIOU-1 relays are identified as Control Relays 1~4.
•
BIOU-2 relays are identified as Control Relays 5~8.
Enter the BOIU PCB number.
Note
BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
•
NOT USE – if the relay is not used.
•
PAGE MUTE – External BGM mute control activates during an
external page (see
•
NIGHT BELL – Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see
102" on page
13-12).
•
NIGHT RELAY – Night Mode Control activates continuously
during the system Night Mode (see
13-18).
•
DOOR LOCK – Door Lock Control activates when a telephone's
Door Unlock button is pressed (see
13-76).
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Summary
"Program 503" on page
13-73).
"Program 105" on page
"Program 508" on page
"Program