Dit Assignment - Toshiba Strata CTX Programming Manual

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

310 DIT Assignment

Prerequisite Program:
This program assigns DIT Number Analysis Table for DIT trunks. DIT trunks are ground and loop start
trunks.
1. Complete the
Record Sheet"
2. From the Program Menu, click
Trunk > Assignment, then click the
DIT tab. The DIT Assignments
screen displays (shown right).
3. Enter Trunk equipment number
field. Enter Program 310 data.
• List – to view a summary list of
programmed Trunks timers.
• Copy – to copy to trunk timer
ports.
4. Click Submit.
F
IELD
Line No.
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
300
on page 6-6
"Trunk Timer/DIT
on
page
D-27.
D
ESCRIPTION
Enter the trunk equipment number. Equipment numbers are required when
assigning a new trunk to the system. It can also be used to display the
equipment location of existing trunks.
Example: If a line should be assigned to an RCOU in cabinet shelf 5, slot 2,
circuit 3, enter 050203.
Possible values: xx = cabinet 01~07; yy =slot 01~10; zz = circuit 01~08 or
Cabinet numbers:
CTX100 – Select 01 for Base and Expansion cabinet.
CTX670 – Select 01 for Base and 02~07 respectively for each Expansion
cabinet.
Slot numbers:
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion slots.
Channel 01~24 (CTX670).
xx = cabinet 01; yy =slot 01~08; zz = circuit 01~24 or
Channel (CTX100)
(default = no value).
Trunks
300 Trunk Assignment
6-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx100Strata ctx670