System Timer - Toshiba Strata CTX Programming Manual

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

System

104 System Timer

104 System Timer
Prerequisite Program:
This command assigns the system timers. System timers set a variety of times to control calls and features
for the Strata CTX.
1. From the Program Menu click
System > System Timer. System
Timer Assignment screen displays
(shown right).
2. Select the desired timer value for
each of the 19 fields.
3. Click Submit.
F
IELD
01 ACB Callback Timer
02 ACB Cancel Recall
Timer
03 Park Recall Timer
04 Camp-on Timer
05 SMDR Valid Call Timer
06 Tandem Timer #1
07 Tandem Timer #2
4-10
None
D
ESCRIPTION
This is used for Internal busy calls. Select the Automatic Callback (ACB) timer. A
callback will be attempted for this specified amount of time before being cancelled.
Possible values: 5~180 sec. (default = 30)
Select the ACB overall timer value. This value establishes a limit for registering a
callback. Once the timer expires, the callback will be cancelled.
Possible values: 5~180 min. (default = 30)
Select the Park timer value. This sets the length of time a call can remain in Park.
Possible values: 10~600 sec. (default = 120)
Select Camp-on timer value. This sets the time needed to remain off-hook prior to
Camp-on being automatically activated.
Possible values: 5~15 sec. (default = 10)
The length of time that a call should be active before being captured by SMDR. The
SMDR Answer timer sets a default time for when an outgoing call will be
considered to be answered for SMDR reporting when a true answer signal is not
returned from the public network. Setting the time short will include calls that may
not be completed, setting the time too long may exclude short calls that are
answered and terminated in a short time.
Possible values: 0~180 sec. (default = 10)
Select timer for a Trunk-to-trunk connection for which neither CO Line has release
supervision, a timer is needed to release the call if no user monitoring has taken
place.
Possible values: 0~3600 sec. (default = 300)
This timer provides a time to allow an external user to dial a digit to extend the
disconnect time when the connection is unsupervised. This feature is used
primarily with DISA service.
Possible values: 0~180 (default = 30)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03