Fan Pack (Intake - Fans 5, 6, 7 And 8) - Christie CP2210 Service Manual

Hide thumbs Also See for CP2210:
Table of Contents

Advertisement

Fan Pack (Intake - Fans 5, 6, 7 and 8)

caught in fan blades.
The fan pack is located directly behind the air fil-
ter on the front of the projector and consists of
four fans. If one fan fails, the entire fan pack must
be changed.
(Estimated Replacement Time: 12 minutes)
1. Remove the top lid. Refer to
page
5-7.
2. Remove the high security lid. Refer to
High Security Lid, on page
3. Remove the air filter cover and filter. Refer to
5.5.1 Air Filter Cover, on page
4. Disconnect the four fan power harnesses via
the inline connectors (Figure 5-63). For
details, refer to the Interconnect Drawing.
5. Pull the plunger located in the high security
compartment to release the fan pack. Refer to
Figure 5-54.
6. Remove the fan pack.
7. Reverse the above steps to reinstall.
NOTE: Use needle nose pliers to pull the
rubber isolators through the fan mounting
holes.
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)
Use caution when working in and around fan assemblies. Fingers can get
5.5.5 Top Lid, on
5-7.
5-5.
Section 5: Parts and Module Replacement
5.5.6
Figure 5-63 Intake Fan Harnesses
5-45

Advertisement

Table of Contents
loading

Table of Contents