5.5.19 Standby Power Supply

UV HAZARD! Always wear protective safety clothing and a face shield when performing
service with the safety shield removed and a lamp installed.
The standby power supply (Figure 5-23) is secured to the projector housing within the lamp compartment next
to the lamp blower.
(Estimated Replacement Time: 15 minutes)
1. Remove the top lid. Refer to
5-7.
2. Remove the safety shield. Refer to
Shield, on page
3. Open the lamp door. Refer to
page
5-9.
4. Remove the lamp (if installed). Refer to
Lamp Replacement, on page
5. Remove the top bracket by loosening the captive
screw, shown in Figure 5-22.
6. Remove the AC power cord from the bottom of the
power supply. (Figure 5-23)
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)
5.5.5 Top Lid, on page
5.5.12 Safety
5-10.
5.5.10 Lamp Door, on
5-13.
Figure 5-23 Standby Power Supply
Section 5: Parts and Module Replacement
5.5.15
Figure 5-22 Power Supply Bracket