Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
NONE
Moving lens mount to a specified vertical position with a specified direction.
RNGN
Motor moving range in negative direction. Read-only.
RNGP
Motor moving range in positive direction. Read-only.
RSET
Move motor to the center flag then move back to current position. Only valid parameter for this command
is 1. Set only command.
STRT
Start motor moving in specified direction, where direction can be (-1, 1). Write-only for v1.3 or newer.
STOP
Stops the motor. Write-only for v1.3 or newer.
MOVR
Moves the motor a given number of steps based on the current location. Write-only for v1.3 or newer.
EXAMPLES:
(LVO 500 1) Move lens to position 500 along vertical axis with positive approach
(LVO 500 -1) Move lens to position 500 along vertical axis with negative approach
(LVO+C101 -500 1) Set lens vertical position for channel 1 to -500 with positive approach
(LVO ?) Return current motor position along vertical axis and direction
(LVO+CALB 1) Calibrate the vertical axis
(LVO+RSET 1) Reset the vertical axis
(LVO+STRT 1) Starts motor moving in positive direction
(LVO+STOP) Stops motor
(LVO+MOVR -100) Move motor 100 steps in negative direction
(LVO+MOVR 200) Move motor 200 steps in positive direction
Measured Color (MCG)
Select the Measured Color Gamut file. This file describes the native colorimetry for the projector as installed and is
required for accurate color processing in the cinema electronics. This control is per channel to allow for different
colorimetry for applications such as 3D.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select measured color gamut for the current channel.
EXAMPLES:
(MCG+C108 "Nominal") Use file "Nominal" on channel 108
(MCG+C108?) Get measured color file name on channel 108
(MCG?L) List all entries of measured color control
Channel Name (NAM)
Set the descriptive channel name for the specified channel
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select channel name for the current channel.
EXAMPLES:
(NAM+C108 "Scope 2.39") Set channel name for channel 108
(NAM+C108?) Get channel name for channel 108
CP2210 Service Manual