Yellow Notch Filter Adjustment; Adjusting Lamp Position (Lamploc ) - Christie CP2210 Service Manual

Hide thumbs Also See for CP2210:
Table of Contents

Advertisement

Section 3: Service Setup
3.4

Yellow Notch Filter Adjustment

UV HAZARD! When servicing the projector with the top lid removed anyone within the
immediate vicinity must wear safety glasses with side shields.
The angle at which light passes through the yellow notch filter affects the final color of light arriving at the
light engine, which in turn affects color accuracy in projected images. By carefully adjusting the yellow notch
filter angle while using a spectrophotometer (such as the SpectraScan PR650) to measure the CIE 1931 color
coordinates of a full green image, the precise green color coordinates, which are crucial for producing accurate
colors for the final display, can be obtained. Adjust the yellow notch filter whenever it is moved or replaced, or
when a new Illumination Optics System (IOS) is installed.
1. Set up a spectrophotometer, such as the SpectraScan PR650, at the image in the theatre.
2. With the top lid removed, display a full green field.
3. Measure the green coordinates using a spectrophometer.
4. Locate the adjustment screw on the center of the yellow notch filter frame and adjust as necessary to obtain
the following coordinates:
• x = 0.265 (±0.02)
• y = 0.690 (±0.02)
3.5
Adjusting Lamp Position (LampLOC
LampLOC
is a required adjustment after servicing many of the projector's optical components. The
adjustment can be performed Automatically or Manually from the Advanced Setup: LampLOC Setup
window. Perform LampLOC
the screen for the life of the lamp. Once LampLOC
and distanced correctly from the remainder of the illumination system.
Before adjusting LampLOC
• The lamp must be ON and the douser (shutter) is OPEN during adjustment. A 10-minute warm-up is recom-
mended.
• Display a white test pattern. This is recommended to allow you to view LampLOC
3-4
to adjust the lamp position for optimal lamp performance and peak brightness at
, ensure the following criteria are met:
)
adjustment is complete, the lamp will be well-centered
progress on-screen.
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)

Advertisement

Table of Contents
loading

Table of Contents