Intelligent Light System Config (ILS)
Enable/disable the Intelligent Lens System for each channel.
SUBCODE
DESCRIPTION OF USE
ACLB
Enable/disable the Auto Lens Mount and Lens reset feature. Once ACLB is turned on, lens mount and lens
system will be reset automatically when system is powered on.
CALB
Calibrate travel range and backlash on specified. Only valid parameter for this command is 5. SET only
command.
CSTS
Motor calibration status (0-100%)
INST
Sets ILS to installed
NONE
Enable/Disable the Intelligent Lens System for each channel. (1/0)
RSET
Move motor to center flag and then move back to current position. Only valid parameter for this command
is 5. SET only command.
RSTS
Motor reset status (0-100%)
EXAMPLES:
(ILS 1) Enable ILS, lens will be moved to the position in each channel
(ILS 0) Disable ILS, position data in each channel will not be used. Moving lens will not affect any channel setting
(ILS+CALB 5) Calibrate all axes of the lens. Set only command
(ILS+RSET 5) Reset all axes of the lens
(ILS+ACLB 1) Reset lens automatically when power on
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)
Section 7: Serial API
7-7