Section 7: Serial API
Internal Media Block Installed/Device Type (IMB)
Access Level: Advanced
Min Power Level: Power Down
Used to set or query whether an IMB is installed or not. Use the DEVT subcode to set the device type.
SUBCODE
DESCRIPTION OF USE
DEVT
Set device type from the list of devices.
None
Set or query installed state of IMB.
EXAMPLES:
(IMI 1) Set to IMB installed.
(IMI+DEVT?L) List valid device types.
(IMI+DEVT?) Query current device type.
Start Interrogator, check interrogator status (INT)
SUBCODE
DESCRIPTION OF USE
BASC
Start a basic interrogation (set only)
ENHA
Start an enhanced interrogation (set only)
STAT
Responds with 2 values: currently running (1 if running) and result file.
EXAMPLES:
(INST+BASC 1) Run a basic interrogation (set only)
(INT+STAT?) Query interrogator status. Returns (INT+STAT!00100 00000 "Interrogator_Enhanced_20101103194849.7z"),
which means the interrogator is 100% finished, not currently running and the latest interrogator file that was generated is named
"Interrogator_Enhanced_201001103194849.7z" and can be found on the projector's FTP server.
Internal Test Pattern (ITP)
List and select internal test patterns. This command also creates the customized test pattern list from the internal
test patterns. The list of available test patterns is determined by what files are loaded on the TI cinema electronics.
SUBCODE
DESCRIPTION OF USE
FULL
Set(1)/Reset(0) full screen size
KEEP
When KEEP=1, don't disable test pattern when changing channels
NOCR
NOCR set non-correction test patterns for measured color. Valid range is 0 to 6
NONE
Select test pattern from full list of defined test patterns
STUP
Add test pattern from full list of defined test patterns to the user list
USER
Select test pattern from user defined test pattern list
EXAMPLES:
(ITP ?) Get current test pattern, 0 means no test pattern is used.
(ITP 4) or (ITP " ") Use number or string to set test pattern
(ITP+USER 4) or (ITP+USER " ") Use number or string to set test pattern from user's test pattern list.
(ITP+FULL 1) Use full screen size
(ITP+FULL 0) Use active channel screen file
(ITP+NOCR 1) Set non-correction test patterns for measured color you can use
(ITP+STUP "DC2K Framing Green, DC2K Framing Red") Add these two test patterns to the user list
(ITP+STUP 1 3) Add these two test patterns indexed in the ITP list to the user list
Lamp Intensity Calibration (LCA)
7-8
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)