Christie CP2210 Service Manual page 110

Hide thumbs Also See for CP2210:
Table of Contents

Advertisement

Section 7: Serial API
EXAMPLES:
(LDB+C108 1) Bypass link decrypter on channel 108.
(LCT 0) Use link decrypter on current channel (i.e. do not bypass).
(LCT+C108?) Get value for LDB on channel 108.
Link Decrypter Installed (LDI)
Access Level: Advanced
Min Power Level: Power Down
Set LD to installed or not installed.
SUBCODE
DESCRIPTION OF USE
None
Set to 1 to installed and 0 to not installed.
EXAMPLES:
(LDI 1) Set LD installed.
Lamp Intensity Calibration (LEN)
Define model and serial number for primary installed lens and auxiliary lens.
SUBCODE
DESCRIPTION OF USE
AMOD
Auxiliary lens model
ASER
Auxiliary lens serial number
MMOD
Main lens model
MSER
Main lens serial number
NONE
Not available
EXAMPLES:
(LEN+MMOD?L) List supported lens model
(LEN+AMOD?L) List supported auxiliary lens model
(LEN+MMOD 1 Set lens model
(LEN+MSER "xxxx") Set lens serial number
Lens Horizontal Position Adjustment (LHO)
Adjust lens offset to specific horizontal position with a specified direction. NOTE: This command can only be
used to update the current ILS file. Changing the horizontal offset for the current channel will change the horizon-
tal offset for any channel using the same ILS file.
Use command without subcode:
If ILS is ON, motor will move to specified steps and save data to the active channel.
If ILS is OFF, motor will move to specified steps, do not save data to the active channel.
SUBCODE
DESCRIPTION OF USE
BACN
Motor backlash in negative direction. Read-only.
BACP
Motor backlash in positive direction. Read-only.
CALB
Calibrate travel range and backlash on specified. Only valid parameter for this command is 1. Set only command.
Cxxx
Replace xxx with the channel number. Valid range is 101-164.
NONE
Moving lens mount to a specified horizontal position with a specified direction.
RNGN
Motor moving range in negative direction. Read-only.
RNGP
Motor moving range in positive direction. Read-only.
RSET
Move motor to the center flag then move back to current position. Only valid parameter for this command is 1. Set only command
7-10
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)