Show Optical-Inform Threshold-Alarm - Zte ZXR10 8900 Series Command Reference Manual

10 gigabit routing switch
Hide thumbs Also See for ZXR10 8900 Series:
Table of Contents

Advertisement

Example
Purpose
Command Modes
Syntax
Syntax
Description
Instruction
Example
This example shows how to cancel the link up alarm and the SNMP
TRAP information of the shielding interface fei_1/1, fei_1/2 and
fei_1/3.
ZXR10#show
optical-inform
High Alarm
High Warn
Temperature
Threshold
Port
(Celsius)
(Celsius) (Celsius) (Celsius) (Celsius)
-----------------------------------------------------------
gei_1/1
48.1
100.0
gei_1/2
34.9
100.0
ZXR10#Show
optical-inform
High Alarm
High Warn
Voltage Threshold Threshold
Port
(Volts)
(Volts)
------------------------------------------------------
gei_1/1
3.30
6.50
gei_1/2
3.30
6.50
Different displaying information for different optical modules. The
optical module information is provided by the drive.
show optical-inform
threshold-alarm
Use this command to display the optical module threshold alarm:
temperature, voltage, circuit, sending and receiving power. It sup-
ports the view of single port and veneer.
Privileged EXEC
show optical-inform threshold-alarm [ npc <slot>| interface
<interface-name>]
interface <
interface-name >
npc <slot>
It only supports the physical interface.
Enable the optical module on the interface first, then it will display
the optical module information: optical-inform monitor {ena
ble | disable}.
This example shows how to cancel the link up alarm and the SNMP
TRAP information of the shielding interface fei_1/1, fei_1/2 and
fei_1/3.
ZXR10#show
optical-inform
High Alarm
High Warn
Temperature
Threshold
Port
(Celsius)
(Celsius) (Celsius) (Celsius) (Celsius)
-----------------------------------------------------------
gei_1/1
48.1
100.0
gei_1/2
34.9
100.0
ZXR10#Show
optical-inform
High Alarm
High Warn
Voltage Threshold Threshold
Port
(Volts)
(Volts)
Confidential and Proprietary Information of ZTE CORPORATION
Chapter 2 Interface Configuration
detail
temperature
Low Warn
Low Alarm
Threshold
Threshold
100.0
0.0
100.0
0.0
detail
Voltage
Low Warn
Low Alarm
Threshold Threshold
(Volts)
(Volts)
6.50
3.50
6.50
3.50
the interface name
the slot number of the line card
detail
temperature
Low Warn
Low Alarm
Threshold
Threshold
100.0
0.0
100.0
0.0
detail
Voltage
Low Warn
Low Alarm
Threshold Threshold
(Volts)
(Volts)
Threshold
0.0
0.0
(Volts)
3.50
3.50
Threshold
0.0
0.0
(Volts)
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents