Figure 3-67: Coders - AudioCodes Mediant 1000 User Manual

Voice-over-ip (voip) sip media gateways
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

SIP User's Manual
To configure the device's coders, take these 9 steps:
1.
Open the 'Coders' page (Configuration tab > Protocol Configuration menu >
Protocol Definition submenu > Coders page item).
2.
From the 'Coder Name' drop-down list, select the coder you want to use. For the full
list of available coders and their corresponding attributes, refer to the table below.
3.
From the 'Packetization Time' drop-down list, select the packetization time (in msec)
for the selected coder. The packetization time determines how many coder payloads
are combined into a single RTP packet.
4.
From the 'Rate' drop-down list, select the bit rate (in kbps) for the selected coder.
5.
In the 'Payload Type' field, if the payload type for the selected coder is dynamic, enter
a value from 0 to 120 (payload types of 'well-known' coders cannot be modified). The
payload type identifies the format of the RTP payload.
6.
From the 'Silence Suppression' drop-down list, enable or disable the silence
suppression option for the selected coder.
7.
Repeat steps 2 through 6 for the second to fifth optional coders.
8.
Click the Submit button to save your changes.
9.
To save the changes to flash memory, refer to ''Saving Configuration'' on page 265.
Notes:
Version 5.4
Figure 3-67: Coders Page
Each coder (i.e., 'Coder Name') can appear only once.
If packetization time and / or rate are not specified, the default value is
applied.
Only the packetization time of the first coder in the coder list is declared
in INVITE / 200 OK SDP, even if multiple coders are defined.
For G.729, it's also possible to select silence suppression without
adaptations.
If the coder G.729 is selected and silence suppression is disabled (for
this coder), the device includes the string 'annexb=no' in the SDP of the
relevant SIP messages. If silence suppression is enabled or set to
'Enable w/o Adaptations', 'annexb=yes' is included. An exception to this
logic is when the remote gateway is a Cisco device (IsCiscoSCEMode).