ini File Parameter
DisableWebTask
ResetWebPassword
WelcomeMessage
DisableWebConfig
HTTPport
SIP User's Manual
[0] = Enable Web management (default).
[1] = Disable Web management.
Resets the username and password of the primary and secondary
accounts to their defaults.
[0] = Password and username retain their values (default).
[1] = Password and username are reset (for the default username
and password, refer to User Accounts).
Note: The username and password cannot be reset from the Web
interface (i.e., via AdminPage or by loading an ini file).
This ini file table parameter configures the Welcome message that
appears after a Web interface login. The format of this parameter is as
follows:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
WelcomeMessage 1 = "..." ;
WelcomeMessage 2 = "..." ;
WelcomeMessage 3 = "..." ;
[\WelcomeMessage]
For Example:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
WelcomeMessage 1 = "**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome message ***" ;
WelcomeMessage 3 = "**********************************" ;
[\WelcomeMessage]
Notes:
Each index represents a line of text in the Welcome message box. Up
to 20 indexes can be defined.
If this parameter is not configured, no Welcome message box is
displayed.
For a description on using ini file table parameters, refer to ''Structure
of ini File Table Parameters'' on page 293.
Determines whether the entire Web interface is in read-only mode.
[0] = Enables modifications of parameters (default).
[1] = Web interface in read-only mode.
When in read-only mode, parameters can't be modified. In addition, the
following pages can't be accessed: 'Web User Accounts', 'Certificates',
'Regional Settings', 'Maintenance Actions' and all file-loading pages
('Load Auxiliary Files', 'Software Upgrade Wizard', and 'Configuration
File').
Note: To return to read/write after you have applied read-only using this
parameter (set to 1), you need to reboot your device with an ini file that
doesn't include this parameter, using the BootP/TFTP Server utility (refer
to the Product Reference Manual).
HTTP port used for Web management (default is 80).