Enabling And Disabling The Root Of A Point-To-Multipoint Soft-Pvc Connections - Cisco Catalyst 8540 MSR Configuration Manual

Atm switch router software configuration guide
Hide thumbs Also See for Catalyst 8540 MSR:
Table of Contents

Advertisement

Chapter 7
Configuring Virtual Connections
Command
Step 2
Switch(atmsoft-p2mp)# upc {drop | pass | tag}
Step 3
Switch(atmsoft-p2mp)# cttr {rx index | tx index} Configures the connection traffic table row type
The row index for cttr rx and cttr tx must be configured before using this optional parameter. See
Note
Chapter 9, "Configuring Resource Management."
traffic table row of same service category with 0 traffic parameter values must be specified.
Examples
The following example enables the early packet discard option on the point-to-multipoint soft PVC
connection configured on an ATM interface:
Switch# config terminal
Enter configuration commands, one per line.
Switch(config)# interface atm 0/0/1
Switch(config-if)# atm soft-vc 50 100 p2mp
Switch (atmsoft-p2mp)# packet-discard on
The following example configures the UPC (Usage-Parameter-Control) to drop all cells that do not
conform to the configured traffic contract on the point-to-multipoint soft PVC connection:
Switch(atmsoft-p2mp)# upc drop
The following example configures CTTR (connection traffic table row) receive and transmit indexes on
the point-to-multipoint soft PVC connection:
Switch(atmsoft-p2mp)# cttr rx 3 tx 64000

Enabling and Disabling the Root of a Point-to-Multipoint Soft-PVC Connections

To enable or disable the root of a point-to-multipoint Soft PVC connection, perform the following steps,
beginning in ATM Soft PVC point-to-multipoint configuration mode:
Command
Step 1
Switch(atmsoft-p2mp)# disable
Step 1
Switch(atmsoft-p2mp)# enable
The disable option releases all the parties of the connection, and the Soft-PVC connection appears in
Note
the NOT_CONNECTED state. No retry will occur until you enable the Soft-PVC using the enable
option.
OL-7396-01
Configuring Point-to-Multipoint Soft PVC Connections
Purpose
Configures the UPC options on a
point-to-multipoint soft PVC connection.
and index on a point-to-multipoint soft PVC
connection.
For non-UBR service categories a transmit connection
End with CNTL/Z.
Purpose
Disables the root of a point-to-multipoint
Soft PVC connection and releases all parties.
Enables the root of a point-to-multipoint
Soft PVC connection.