Cisco Catalyst 8540 MSR Configuration Manual page 666

Atm switch router software configuration guide
Hide thumbs Also See for Catalyst 8540 MSR:
Table of Contents

Advertisement

Configuring Frame Relay to ATM Virtual Connections
If the interworking soft PVC terminates on an ATM interface, the default interworking type is service
Note
interworking in translation mode.
Frame Relay to ATM Service Interworking Soft PVC Configuration Example
Use the following steps to configure the service interworking soft PVC between Switch A and switch B
as shown in
In the following process the source (active) side is serial interface 0/1/0:5 on Switch A and the
Note
destination (passive) side is ATM interface 0/0/1 on Switch B.
On Switch A, use the show vc interface serial command to determine that DLCI 43 is available for use
Step 1
on serial interface 0/1/0:5 Switch A:
Switch-A# show vc interface serial 0/1/0:5
Interface
Serial0/1/0:5
Serial0/1/0:5
Serial0/1/0:5
Serial0/1/0:5
On Switch B, use the show atm addresses command to determine the destination ATM address for ATM
Step 2
interface 0/0/1, which is 47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0010.00.
Switch-B# show atm addresses
Switch Address(es):
47.00918100000000E01E199904.00E01E808601.00 active
Soft VC Address(es) :
47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0000.00 ATM0/0/0
47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0010.00 ATM0/0/1
47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0020.00 ATM0/0/2
47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0030.00 ATM0/0/3
<information deleted>
Step 3
On Switch B, use the show vc interface atm command to determine that VPI/VCI 50/255 is available
for use on ATM interface 0/0/1:
Switch-B# show vc interface atm 0/0/1
Interface
ATM0/0/1
ATM0/0/1
ATM0/0/1
Step 4
The following example configures a service interworking soft PVC in transparent mode on Switch A
using the information obtained in the previous steps:
Switch-A(config)# interface serial 0/1/0:5
Switch-A(config-if)# frame-relay soft-vc 43 dest-address
47.0091.8100.0000.00e0.1e19.9904.4000.0c80.0010.00 vc 50 255 service transparent
After you complete the soft VC configuration, go to
20-39
ATM Switch Router Software Configuration Guide
20-38
Figure
20-9.
Conn-Id Type
54
SoftVC
55
SoftVC
56
SoftVC
66
SoftVC
Conn-Id
Type
0/5
PVC
0/16
PVC
0/18
PVC
and verify the connection.
Chapter 20
Configuring Frame Relay to ATM Interworking Port Adapter Interfaces
X-Interface
X-Conn-Id
Serial3/0/0:3
54
Serial3/0/0:2
55
ATM0/1/3
0/45
ATM1/1/0
0/100
X-Interface
X-Conn-Id
ATM2/0/0
0/58
ATM2/0/0
0/44
ATM2/0/0
0/71
Display Frame Relay Interworking Soft PVCs, page
Encap
Status
SoftVC
UP
SoftVC
UP
SVC
UP
SoftVC
UP
Encap
Status
QSAAL
UP
ILMI
UP
PNNI
UP
OL-7396-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 8510 msrLightstream 1010

Table of Contents