Threshold Group For Tbr Classes - Cisco Catalyst 8540 MSR Configuration Manual

Atm switch router software configuration guide
Hide thumbs Also See for Catalyst 8540 MSR:
Table of Contents

Advertisement

Chapter 16
Configuring Tag Switching and MPLS

Threshold Group for TBR Classes

A threshold group utilizes the memory efficiently among VCs of a particular traffic type. Each threshold
group is programmed with a dynamic memory allocation profile that maps into the needs of the
connections of a particular service class. There are 16 threshold groups (0 to 15) available on the ATM
switch router. Each threshold group has a set of eight regions, and each region has a set of thresholds.
When these thresholds are exceeded, cells are dropped to maintain the integrity of the shared memory
resource.
Each ATM Forum service category is mapped into a distinct threshold group. All the connections in a
particular service category map into one threshold group. Similarly, all the Tag Bit Rate (TBR) classes
have best effort traffic and the service differentiation comes mainly by giving different weights. Each of
the TBR classes map into four different threshold groups whose parameters are the same as the
unspecified bit rate (UBR) threshold group.
Table 16-5
for the Catalyst 8540 MSR.
Table 16-5 Threshold Group Parameters for TVCs (Catalyst 8540 MSR)
Group
7
8
9
10
Table 16-6
for the Catalyst 8510 MSR and LightStream 1010 ATM switch routers.
Table 16-6 Threshold Group Parameters for TVCs (Catalyst 8510 MSR and LightStream 1010)
Group
7
8
9
10
Each threshold group is divided into eight regions. Each region has a set of thresholds that are calculated
from the corresponding threshold group parameters given in
in any one of the regions depending on the fill level (cell occupancy) of that group. And that region is
used to derive the set of thresholds which apply to all the connections in that group.
OL-7396-01
shows the threshold group parameters mapped to the connections in all of the TBR classes
Maximum
Maximum
Queue
Minimum
Cells
Limit
Queue Limit
131,071
511
31
131,071
511
31
131,071
511
31
131,071
511
31
shows the threshold group parameters mapped to the connections in all of the TBR classes
Maximum
Maximum
Queue
Minimum
Cells
Limit
Queue Limit
65,535
511
31
65,535
511
31
65,535
511
31
65,535
511
31
Threshold Group for TBR Classes
Mark
Discard
Threshold
Threshold
25%
87%
25%
87%
25%
87%
25%
87%
Mark
Discard
Threshold
Threshold
25%
87%
25%
87%
25%
87%
25%
87%
Table
16-5. The threshold group might be
ATM Switch Router Software Configuration Guide
Use
TBR_1
TBR_2
TBR_3
TBR_3
Use
TBR_1
TBR_2
TBR_3
TBR_3
16-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 8510 msrLightstream 1010

Table of Contents