Configuring A Soft Pvc For Structured Ces With Cas And On-Hook Detection Enabled - Cisco Catalyst 8540 MSR Configuration Manual

Atm switch router software configuration guide
Hide thumbs Also See for Catalyst 8540 MSR:
Table of Contents

Advertisement

Chapter 19
Configuring Circuit Emulation Services
cas ON, cell_header 0x100 (vci = 16)
Configured CDV 2000 usecs, Measured CDV unavailable
De-jitter: UnderFlow unavailable, OverFlow unavailable
ErrTolerance 8, idleCircuitdetect OFF, onHookIdleCode 0x0
state: VcActive, maxQueueDepth
Partial Fill:
Active SoftVC
Src: atm addr 47.0091.8100.0000.00e0.4fac.b401.4000.0c81.8030.10 vpi 0, vci 16
Dst: atm addr 47.0091.8100.0000.00e0.4fac.b401.4000.0c81.803c.10
The following example displays the CAS status for the destination port CBR 3/0/3 (shown
in
Figure
CESwitch# show ces circuit interface cbr 3/0/3 1
Circuit: Name CBR-PVC-B, Circuit-state ADMIN_UP / oper-state UP
Interface CBR3/0/3, Circuit_id 1, Port-Type T1, Port-State UP
Port Clocking network-derived, aal1 Clocking Method CESIWF_AAL1_CLOCK_SYNC
Channel in use on this port: 10-13
Channels used by this circuit: 10-13
Cell-Rate: 698, Bit-Rate 256000
cas ON, cell_header 0xC100 (vci = 3088)
Configured CDV 2000 usecs, Measured CDV unavailable
De-jitter: UnderFlow unavailable, OverFlow unavailable
ErrTolerance 8, idleCircuitdetect OFF, onHookIdleCode 0x0
state: VcActive, maxQueueDepth
Partial Fill:
Passive SoftVC
Src: atm addr 47.0091.8100.0000.00e0.4fac.b401.4000.0c81.803c.10 vpi 0, vci 3088
Dst: atm addr 47.0091.8100.0000.00e0.4fac.b401.4000.0c81.8030.00
Configuring a Soft PVC for Structured CES with CAS and On-Hook Detection
Enabled
This section outlines the additional steps that you must take to activate the on-hook detection
(bandwidth-release) feature in a 1 x 64 structured CES circuit.
To configure a soft PVC for structured CES with CAS and on-hook detection enabled, follow these steps,
beginning in global configuration mode:
Command
Step 1
Switch(config)# interface cbr card/subcard/port
Switch(config-if)#
Step 2
Switch(config-if)# shutdown
Step 3
Switch(config-if)# ces circuit circuit-id [cas]
[on-hook-detect pattern]
Step 4
Switch(config-if)# no shutdown
Example
The following example shows how to configure on-hook detection on the soft PVC with structured CES
and CAS enabled in
in
Figure
CESwitch(config)# interface cbr 3/0/0
OL-7396-01
47, Structured Data Transfer 98
19-6):
47, Structured Data Transfer 98
Configuring a Soft PVC for Structured CES with CAS Enabled, page 19-34
19-6):
Configuring T1/E1 Structured (n x 64) Circuit Emulation Services
45, startDequeueDepth
45, startDequeueDepth
Purpose
Selects the physical interface to be configured.
Disables the interface.
Configures channel-associated signalling and
on-hook detection on the CES circuit.
Reenables the interface.
ATM Switch Router Software Configuration Guide
28
28
(shown
19-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 8510 msrLightstream 1010

Table of Contents