Configuring T1/E1 Unstructured Circuit Emulation Services
CESwitch(config-if)# ces dsx1 clock source network-derived
CESwitch(config-if)# ces circuit 0 circuit-name CBR-PVC-B
CESwitch(config-if)# no shutdown
Note
If you do not specify the circuit name and logical name parameters in the command line, the system
automatically assigns a unique default name in the form CBRx/y/z:# for the circuit being configured. For
example, the default name for this particular circuit is CBR3/0/1:0.
Phase 2—Configuring the Source (Active) Side of the Soft PVC
To configure the source (active) side of a soft PVC destination port, follow these steps, beginning in
privileged EXEC mode:
Command
Step 1
Switch# show ces address
Step 2
Switch# configure terminal
Switch(config)#
Step 3
Switch(config)# interface cbr card/subcard/port
Switch(config-if)#
Step 4
Switch(config-if)# shutdown
Step 5
Switch(config-if)# ces aal1 service {structured |
unstructured}
Step 6
Switch(config-if)# ces aal1 clock {adaptive | srts
| synchronous}
Step 7
Switch(config-if)# ces dsx1 clock source
{loop-timed | network-derived}
Step 8
Switch(config-if)# ces circuit circuit-id
circuit-name name
Step 9
Switch(config-if)# ces pvc circuit-id
dest-address remote_atm_address vpi vpi vci vci
[follow-ifstate]
Step 10
Switch(config-if)# no shutdown
ATM Switch Router Software Configuration Guide
19-16
Chapter 19
Configuring Circuit Emulation Services
Purpose
Shows the CES address and VPI/VCI for the
destination end of the circuit.
Use this command to retrieve the destination's
VPI/VCI.
At the privileged EXEC prompt, enters global
configuration mode.
Selects the physical interface to be configured.
Disables the interface.
Configures the CES interface AAL1 service type.
Configures the CES interface AAL1 clock mode.
Configures the CES interface clock source.
Configures the CES interface circuit identifier
and circuit name.
Note
For unstructured service, use 0 for the
circuit identifier.
Configures the soft PVC to the destination
CES-IWF ATM addresses and VPI/VCI of the
circuit.
Note
Use the destination's VPI/VCI, which
you retrieved in Step 1.
The follow-ifstate keyword configures the source
(active) port circuit status to follow the status of
the physical interface. The default circuit setting
ignores the status of the physical interface.
Reenables the interface.