Installation, Maintenance, and Upgrade
Install the FIPS Opacity Shield
Note
Because the FIPS opacity shield covers the serial number on the chassis, the CO should copy the serial number
and store it in a secure place. The serial number is needed when you call Cisco TAC. See
Location
Note
You can only install the FIPS opacity shield with the desktop mount or wall mount. The rack mount does not
support the FIPS shield. See
Before you begin
Caution
This procedure should be performed only by the Crypto Officer (CO).
You need the following to install the FIPS opacity shield:
• #1 Phillips head screwdriver
• The following items from the FIPS kit (part number 69-100649-01):
Install the FIPS Opacity Shield , on page 1
for the location of the serial number.
Desktop-Mount the Chassis
• One FIPS opacity shield (part number 800-106088-01)
• Three M3 x 66 mm (part number 48-0384-01) screws used to attach the FIPS opacity shield to the
chassis
• Nine Tamper Evidence Labels (TELs) (part number 47-25553-01)
and
Wall-Mount the Chassis
Installation, Maintenance, and Upgrade
Serial Number
for more information.
1

Advertisement

loading

Summary of Contents for Cisco Firepower 1010

  • Page 1 Note Because the FIPS opacity shield covers the serial number on the chassis, the CO should copy the serial number and store it in a secure place. The serial number is needed when you call Cisco TAC. See Serial Number Location for the location of the serial number.
  • Page 2 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Note The TELs are made of a special thin gauge vinyl with self-adhesive backing. Once the CO attaches them on the chassis, any attempt to open the chassis damages the TELs or the chassis cover. Because the TELs have nonrepeated serial numbers, the CO can inspect them for damage and compare them against the applied serial numbers to verify whether the chassis has been tampered with.
  • Page 3 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Figure 2: Install Screws on the Bottom of the FIPS Cover FIPS opacity shield Three M3 x 66 mm Phillips screws Step 5 Before you attach the TELs, clean the chassis and FIPS cover of any grease, dirt, or oil with alcohol-based cleaning pads.
  • Page 4 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Figure 3: TELS Placement on the Rear Panel and Bottom of the FIPS Cover TEL 1 on the rear panel of the chassis TEL 2 on the bottom left of the FIPS cover over the screw TEL 3 on the bottom center of the FIPS cover over TEL 4 on the bottom right of the FIPS cover over the...
  • Page 5 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield • See the fips enable command in the Cisco ASA Series Command Reference, A-H Commands for the ASA procedure to enable FIPS mode. What to do next See the Cisco Firepower 1010 Getting Started Guide for further configuration information.
  • Page 6 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Installation, Maintenance, and Upgrade...