4.8
Resetting the Unit to Factory Configuration
In certain situations, it may be desired to reset all VersaSync configurations back
to the factory default configuration. The GNSS location, any VersaSync con-
figurations and the locally stored log files can be cleared via the Web UI.
If VersaSync was assigned a static IP address before cleaning the configurations,
it will be reset to DHCP after the clean has been performed. If no DHCP server is
available after the clean operation, the static IP address will need to be manually
reconfigured.
CHAPTER
•
4
VersaSync User Manual Rev. 12
3. In the
Actions
panel, click
4. In the
Apply License File
5. In the
Upload File
navigate to the location mentioned under the first step, select the license
file, and monitor the installation progress in the
until the application has rebooted.
6. Refresh the browser window, and login to the Web UI again. Re-navigate to
Tools
> Upgrade/Backup, and confirm that the newly installed Option is lis-
ted in the
System Configuration
Note:
Restoring configurations (reloading a saved configuration),
erasing the stored GNSS location and clearing the log files are sep-
arate processes. You may restore one without restoring the others.
4.8 Resetting the Unit to Factory Configuration
Apply License
window, click
window, click
Choose
panel.
File.
Upload New
File.
File. Using the Explorer window,
Status Upgrade
window
293