Power-Up Test Codes - Digital Equipment VAXstation 3100 Maintenance Manual

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

6 Testing
1.2.1 Power-Up Test Codes
The power-up test codes indicate no error, soft errors, status
inf
onnation, or
hard (fatal) error information. Any errors found by power-up tests are listed in
the power-up tests summary. These errors as well as the status of all devices
installed
in
the system are then stored
in
the configuration 1able (TEST 50).
Table
1-4
lisls the test numbers and the devices that are tested during that
particular test. To look at the status of a device, display the configuration
table (enter TEST 50 (T 50) at the console prompt>>>). The configuration
table lists every device in the system and also lists the results of the power-up
tests and self-test. It is updated each time self-test is run. Remember that the
configW'ation table contains the results of the
power-up
tests and self-test and
not the results of the system exerciser.
Table 1-4 Power-Up end Self-Test Commends
Test
Mnemonics
Device
TF
MONO
Base video
TE
CLK
Time-of-year
clock
TD
NVR
Nonvolatile random access memory (RAM)
TC
DZ
Serial line controller
TB
MEM
Memory
TA
MM
Memory management unit
T9
FP
Floating point unit
TS
IT
Interval timer
T7
STR0-1
RX23 diskette drive (model 30 with
ST506iSCSI)
T7
SCSI-A
SCSI-A bus controller on the SCSI/SCSI MSC
module
T6
SCSI-B
SCSI-B bus controller on the SCSI/SCSI MSC
module
T 6 and 7
SCSI-A and
RZ22 and RZ23 disk drives
SCSI-B
T6
SCSI-A and
RRD40 compact disc and adapter board
SCSI-B
T6
SCSI-A and
RZ55 expansion box
SCSI-B

Advertisement

Table of Contents
loading