System Exerciser Error Codes
Table F-6 System Memory Error Codes (XXXX.OOYZ)
Error Codes
Definition
0000.0001
Success-No error
0001.000F
System software error
0002.000F
System software error
0003.000F
System software error
0004.000F
System software error
0005.000F
System software error
0006.000F
System software error
0007.000F
System software error
0008.000F
System software error
0001.00lF
Compare error on system module
0002.00lF
Compare error on option module
0001.002F
P;uity
error on system module
0002.002F
Parity
error on option module
F.4 RX23 Drive Controller (STRG-1 on Model 30)
Controller error code format: TUVV.XYZl
Where
the T indicates the
drive
used during
the
transfer test,
the
U indicates the
results of the transfer test
, the
VV indicates
the
error cowit
(in
hexadecimal)
during the transfer test, and the X, Y, and Z indicate the results of the intenupt
test,
register
test,
and the buffer test
respectively.
Table
F-
7 lists the drive
numbers used during the transfer test (T). Table F-8 lists the error codes for
the U, X, Y, and Z bit positions.
Drive error code format: JKLL.PRS 1
Where the J indicates the drive number, the K indicates the status of the drive,
the LL indicates the error count (in hexadecimal) for the drive. The P, R, and
S indicate the status of the RX23 controller test, the termination code bit from
the interrupt status port register, and the routine test respectively. Table F-7
lists the drive numbers (J). Table F-9 lists the codes for drive status (K).
Table F-10 lists the RX23 controller status codes (P). Table F-8 lists the error
codes for the routine status (S).