Power-Up and Self-Test Error Codes 213
Table E-3 Time-Of-Year Clock (0000.XXXX)
Error Codes
Deftnltlon
0001
No error
0003
Tell dispatcher to check time at the end of the testing.
0004
lnvalid time set
0005
Clock
has not been reset since the last time that battery voltage level
was
low.
0010
Failure
in
time-of-year test
0020
Vrt bit failed to set after
it
was read the first time.
0040
Battery voltage level was down during the clock test.
E.3 Nonvolatile RAM (NVR)
Error code format: 0000.XXXX
Where XXXX is one of the codes listed in Table
E-4.
An error code of 5
indicates that the battery voltage is below an acceptable level for data in the
NVR to be valid.
Table E-4 Nonvolatile RAM Error Codes (0000.XXXX)
Error Codes
Deftnltlon
0001
No error
0004
Battery was down at last entry.
0008
NVR failed.
0080
The
battery check code
in
the NVR did not aggree with the expected
check code.
E.4 Serial Line Controller (DZ)
Error code format: 0000.XXXX
Where the XXXX is one of the error conditions listed
in
Table E-5.